Alpha Source, Inc. is committed to providing products and services that meet or exceed our customer and regulatory requirements.  In the event of a return, the following applies:

  • Please inspect all cartons and verify part numbers and quantities against enclosed packing slip.  All damage, discrepancies or defective merchandise must be reported within 3 business days after receipt. 

  • Customers must first contact our Customer Service department at 1-800-654-9845 to obtain prior approval and a Return Material Authorization (RMA) number. No products will be accepted for return without an RMA number.

  • Items must be carefully packed in a suitable box to avoid damage in shipping.  Package must be properly labeled with RMA paperwork.

  • Non-defective product must be returned in resalable condition, in the original factory carton, with no additional markings or labels applied.

  • Only certain items are returnable.  Disposable (single use) products and non-stock items are not eligible for return unless it is determined that there was an Alpha Source processing error.

  • Merchandise will not be accepted for return after 30 days past the invoice date.

  • Merchandise must be returned to Alpha Source, Inc. within 30 days from the date of issue of the RMA. 

  • Return shipment costs are the responsibility of the customer, unless otherwise stated.

Return of suspected defective product: Issuance of an RMA number does not acknowledge a product defect or authorize credit.  Alpha Source reserves the right to inspect all returned merchandise and issue final determination of its condition.  If a product is returned as defective, and is found not to be defective, it will be returned to the Customer.

Return of Product due to Customer ordering error: Products returned due to customer ordering error may be subject to a restocking fee. The Fee may range from a minimum of $10 to a maximum of $250 depending on the value of the item. The general policy is 25% of the value.

Product Warranty

For additional Warranty and Product Return Information contact Customer Service at 1.800.654.9845.

Alpha Source Warranty

Alpha Source Inc. warrants solely to the purchasing party that the product sold shall be free from defects in material and workmanship; when given normal, proper and intended usage and care, for the scope of the warranty granted to Alpha Source, Inc. and its customers by the applicable manufacturer from the date of shipment from Alpha Source, Inc.

  • Compact Xenon Lamps: 600 hours or one year from date of shipment.
  • All other lamps: Guaranteed to perform at time of delivery

General Basic Warranty for items Manufactured for Alpha Source, Inc. by Access Battery LLC (Capacity warranty covers if the Capacity falls below 80% of rated capacity under normal use and service.)

  • All Lead Acid Batteries: 12 months from date of shipment
  • NiCad Batteries: 12 months from date of shipment
  • NiMH Batteries: 12 months from date of shipment
  • X-Ray Batteries and Kits: 12 months from date of shipment
  • Lithium Ion 12 months from date of shipment
  • Non-rechargeable Batteries: Guaranteed to perform at rated capacity at time of shipment.

Purchaser Responsibility: Purchaser shall notify Alpha Source, Inc. of any product that they believe to be defective. At Alpha Sources options, such products shall be returned by the Purchaser, transportation and insurance prepaid to Alpha Source. Based on examination and testing by the applicable manufacturer, Alpha Source shall repair, replace with comparable product or issue an appropriate credit.

If the Purchaser requires an immediate replacement prior to evaluation, the purchaser may be sent a replacement which they will be billed for. If the returned product passes examination and testing, it will also be returned to the purchaser. If the returned product is found defective, then the customer will be credited for the defective item.

In the event of a warranty adjustment, Alpha Source shall pay appropriate shipping charges, to return product to the purchaser.

Purchasing Help

Purchasing from Alpha Source

At Alpha Source we offer a variety of ordering options that enable ordering over the phone, fax, or through the mail. To place orders by phone call 1-800-654-9845 anytime between 7 a.m. and 5 p.m. (CST) Monday through Friday. We accept fax orders at 1-888-654-9840.

Net 30 Day Billing: with approved credit.

We accept:

  • Credit CardsAmerican Express
  • MasterCard
  • Visa
  • Payment in advance
  • C.O.D.
  • Letters of credit

Special Pricing available for large orders or blanket orders. Please contact us for more information.

Returns require a Return Authorization Number. Where the return is neither defective merchandise nor an error made by Alpha Source, a restocking charge of 25% will apply.

  • Alpha Source will only accept items that are defective or incorrectly shipped. Alpha Source will not accept any returned items without an order Return Authorization Number. Please call Customer Service at 1-800-654-9845 to get a Return Authorization Number or for more information read our Warranty Policy.
  • Merchandise returned in un-saleable condition will be returned to the sender, at the sender's expense, and no credit will be issued.
  • NO cash refunds for returned merchandise.

Product Identification

If you're unsure about what type of product you need, we can help you. Call us at 800-654-9845 or 414-760-2222 with the brand and model of your device and let us advise you, or send e-mail to customer.service@alphasource.com.

FAQ

Shipping

Can I be billed? Do you ship C.O.D.?
Only pre-approved customers may have their orders billed. We can ship orders UPS-COD within the United States.

How does Alpha Source ship purchases?
Alpha Source ships most purchases via UPS (United Parcel Service). Other carriers are also available.

Product Information

Must medical-grade power cords have clear plugs?
The UL and CSA standards do not mandate clear plugs nor are there any restrictions on color.  Many hospitals prefer clear plugs so that internal connections can be inspected visually, quickly and easily.

What is a medical-grade power cord?
The plug determines whether a power cord can be classified as a medical or hospital-grade cord.  Cords used with medical equipment in North America must be hospital-grade and conform to the special requirements contained in the following standards:  Medical equipment standards, UL 2601-1 and CAN/CSA C22.2 no 60601-1; Power supply cord standards, UL 817 and CAN/CSA C22.2 no 21; Attachment plug standards, UL 498 and CAN/CSA C22.2 no 42.
The hospital grade plug conforms to the NEMA 5-15 standard, where the blades are solid brass with nickel plating and the plug includes a cable retention device or strain relief.

Is there a maximum length for medical-grade power cords?
There are no specific maximum lengths for cords noted in the applicable UL or CSA standards but the equipment must pass the leakage current test requirements in UL 2601-1 and CAN/CSA C22.2 no 60601-1. Cord length has an effect on leakage current within a system.

How do you recognize a medical-grade power cord?
North American medical-grade power cords have a "green dot" signifying that they have been designed and tested for grounding reliability, assembly integrity, strength and durability. They are approved by UL and CSA to UL 817 and CAN/CSA C22.2 no 21. The plug must be marked "Hospital Grade" and include a permanent green dot sized 4.8 to 6.4mm in diameter.

Billing

Do you charge sales tax?
Alpha Source charges applicable sales tax on orders billed to addresses within Wisconsin; otherwise we do not charge sales tax.

Can I order if I don't have a credit card?
Yes, Alpha Source accepts checks, wire transfers and money orders in addition to credit cards.
Net 30 day terms may be extended to qualified accounts.

What about International Orders?
International purchases require wire transfers, checks or money orders drawn on US funds. Alpha Source also accepts credit cards for international purchases.

What payment options are available?
Alpha Source accepts Visa, MasterCard, and American Express. We also accept wire transfers, money orders and checks drawn on U.S. funds.

Fiber Optic Cable - Quick Tips

Medical Fiber Optic Cable Quick Tips

Quick TipsGreen Medical Fiber Optic Cable

  • Avoid stretching your fiber optic cable, forming configurations involving sharp angles or kinks, or contact with sharp objects
  • Keep the optical faces from contacting the floor. The resulting scratches will diminish the light output.
  • Any inadvertent cut or puncture will render the fiber optic cable unsafe. It should be taken out of service immediately.

 

For additional information on Alpha Source Medical Fiber Optic Cables or information on how to Build a Medical Custom Cable call 1-800-654-9845.

Fiber Optic Cable - Visual Inspection

How to Perform a Fiber Optic Cable Visual Inspection For Network Data Cables Only

To make sure the fibers are not broken use a visible light "fiber optic tracer" or "pocket visual fault locater" to trace a path from fiber end to end.

For Endoscopic Systems

A light measurement device know as an integrating sphere will provide the most accurate results. It measures light output from the light source, the fiber optic light cables and endoscopes. Radiometers and Photometers can also be used to measure luminous radiation.

Note: Use extreme caution when inspecting medical and industrial fiber optic cables.

 

For additional information on Alpha Source Fiber Optic Cables or information on how to Build a Custom Cable call 1-800-654-9845.

Fiber Optic Cables - Cleaning Tips

Fresh & Clean Medical Fiber Optic Cables Go A Long Way

Medical Fiber Optic CableMedical Fiber Optic CableMedical Fiber Optic CableMedical Fiber Optic Cable

Should the medical fiber optic cable become contaminated before use, clean the cable thoroughly with a soft bristled brush and hand warm water.

Recommended soap solutions: Use a non-oily cleaner or mild soap. Do not use synthetic detergents or oil based soaps as these soaps may be absorbed and may subsequently leak out to cause a tissue reaction.

Medical Fiber Optic Cable Cleaning

      1.      A soft bristled brush used in lukewarm water with mild soap is recommended to remove visible debris.
      2.      Do not use synthetic detergents or oil based soap, as the chemicals may be absorbed into the cable and
               subsequently leak out and cause tissue reactions.
      3.      Rinse thoroughly in warm water followed by a distilled water rinse.

Disinfection of Fiber Optic Cables

Fiber optic cables may be soaked in disinfecting solutions without damage. Usually less than 10 minutes.

Sterilization of Fiber Optic Cables

Medical fiber optic cables are designed to withstand repeated autoclave sterilizations in the following types of sterilizers: standard gravity (Steam) and Steris (System 1). Avoid sterilizing with sharp or pointed instruments!

Following sterilization allow your cable to cool to room temperatures SLOWLY. Do NOT immerse or rinse in cold liquid, as this will cause fiber breakage and extensive light transmitting losses.

For additional information on Alpha Source Fiber Optic Cables or information on how to Build a Custom Cable call 1-800-654-9845.

Fiber Optic Cables - Autoclaving Guidelines
 

Medical Fiber Optic CableGeneral Medical Fiber Optic Cable Autoclaving Guidelines

1.   Standard Gravity Sterilizer: Wrap fiber optic cable in a surgical towel and place in a clean open tray. Sterilize for 30 minutes 250 F at (15 psi.) or 121 C at 1 kg/Cm2.

2.   High Speed Instrument (flash) Sterilizer: Wrap fiber optic cable in a surgical towel and place in a clean open tray. Sterilize for 3 minutes 270 F at (15 psi.) or 132 C at 2kg/Cm2.

* Pressure differential during steam autoclaving may cause small bubbles in the silicone tubing. The bubbles will not affect the fiber optic cable and will dissipate with time.

Sterilization

Medical fiber optic cables are designed to withstand repeated autoclave sterilizations in the following types of sterilizers: standard gravity (Steam) and Steris (System 1). Avoid sterilizing cable with sharp or pointed instruments!

Following sterilization allow your fiber optic cable to cool to room temperature SLOWLY. Do NOT immerse or rinse in cold liquid, as this will cause fiber breakage and extensive light transmitting losses. 

General Guidelines for Steam Autoclave:

Temperature

134 C

                                                                     

PreVac Time

3 Minutes

 

Dry Time

20 Minutes

 

For additional information on Alpha Source Medical Fiber Optic Cables or information on how to Build a Custom Medical Cable call 1-800-654-9845.

Site Map | Privacy | Legal Notice | Contact Us | Employment Opportunities

Copyright © 2002-2011 Alpha Source, Inc.